Smoke & Draft Rated Doors

Protecting ICU patients in the event of a fire.

Smoke & Draft Rated Doors

Our smoke and draft doors are rated to meet a host of requirements and are leakage-rated under UL1784/NFPA 105. They allow hospital personnel to protect patients in ICU environments until smoke is cleared, instead of dangerously transporting critical patients connected to equipment in the event of a fire.

Manual Swing Door

Our Dura-Care 7400 manual swing door is smoke and draft-rated and is available in single, pair, or uneven pair configurations. This door is known for its simple, end-user ease of use, its tight seal for positive pressure, and its convenience for small rooms and spaces.

A Manual swinging door in a hospital setting.

Applications:

  • ICU/CCUs
  • Patient Bathrooms
  • Pressurized Isolation Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same-Day Surgery Rooms
  • Trauma Rooms
  • Equipment Control Rooms

Manual Sliding Doors

Our ProCare8300 2-panel manual sliding door, ProCare 8300BP 4-panel bi-part manual sliding door, Dura-Care 7200 2-panel manual sliding door, and our 3-panel Dura-Care 7500TL and Dura-Care 7500TL-FBO are designed to protect patients with safer transfers and promote healing by eliminating disruptions. These doors are best for patient privacy and frequent patient transports, making them great in ICU/CCUs. Additionally, the ProCare 8300BP is great for optimizing space, and the Dura-Care 7200 is great for retrofitting applications because it is surface-mounted.

Applications:

  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Smoke Rated Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same-Day Surgery Rooms
  • Trauma Rooms
  • Large Office/Meeting Rooms
  • Bariatric Treatment Rooms
A manual sliding door in a hospital setting.

Automatic Doors

Our touchless automation is available for our ProCare 8300A 2-panel and Dura-Care 7500A 3-panel automatic sliding doors. With jamb-mounted touchless wave activation and overhead safety sensors, these doors are great for infection control as well as patient privacy and frequent patient transports.

An automatic door in a hospital setting.

Applications:

  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Smoke Rated Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same-Day Surgery Rooms
  • Trauma Rooms
  • Hospital Pharmacies
  • Operating Rooms

Codes and Standards

  • NFPA 105 is a standard for the installation of smoke door assemblies and other devices that are tested in accordance with air leakage requirements.
  • UL 1784 (Standard for Air Leakage Tests of Door Assemblies and Other Opening Protectives) was developed for areas of health care facilities where smoke infiltration is a concern. It consists of testing at ambient and high temperature (400º F) and ensuring leakage rate does not exceed 3 ft3/minute/sqft at 0.30" WC.

Place a Service Call

Our AADM-certified STANLEY technicians are trained to repair any make and model door.