Trackless Sliding Intensive Care Unit Doors
with breakaway capabilities for patient transport
Trackless Sliding Intensive Care Unit Doors
with breakaway capabilities for patient transport

Guidelines:
- Choose doors with the largest clear door opening for easier patient transport without having to breakaway the door.
- Two-panel doors are more cost-effective, while 3-panel and 4-panel doors have smaller swing out into the patient room or corridor.
- Door frames should be 1/2" smaller than your rough opening.
|
Clear Door Opening* for 7'-0 1/2" Rough Opening |
Clear Door Opening* for 8'-0 1/2" Rough Opening |
Clear Door Opening* for 9'-0 ½” Rough Opening |
2- and 4-PANEL |
|
|
|
38.2" |
44.2" |
50.2" |
|
38.2" |
44.2" |
50.2" |
|
37.4" |
43.4" |
49.4" |
|
35.3" |
41.3" |
47.3" |
|
35.1” |
41.1” |
47.1” |
|
33.3" |
39.3" |
45.3" |
|
3-PANEL |
|
|
|
44.6" |
52.6" |
60.6" |
|
39.5" |
47.5" |
55.5" |

MODELS
ProCare8300: 2-panel manual sliding door. Newly designed to protect patients with safer transfers and promote healing by eliminating disruptions. Clear door opening* is 44.2” on an 8’ door and 50.2 on a 9’ door.
Dura-Care 7500 Series: 3-panel manual sliding doors. Clear door opening* is 47.5” on an 8’ door and 55.5” on a 9’ door.
*Without positive latch
SOLUTIONS FOR
- Patient Privacy
- Frequent Breakaway for Patient Transports
APPLICATIONS
- ICU/CCUs
- Pressurized Isolation Rooms
- Smoke Rated Rooms
- Emergency Department Treatment Rooms
- Pre/Post Surgery Rooms
- Same Day Surgery Rooms
- Trauma Rooms
- Large Office/Meeting Rooms
- Bariatric Treatment Rooms

MODELS
ProCare 8300BP: This compact 4-panel bi-part manual sliding door is STANLEY’s newest alternative to the standard sliding ICU door. Designed to protect patients with safer transfers and promote healing by eliminating disruptions. Breakaway arc is 23.7” on a 8’ and 26.7”on an 9’ door.
Dura-Care 7500 TL-FBO: 3-panel sliding doors. Breakaway arc is 32.8”on an 8’ door. And 36.8” on a 9’ door.
SOLUTIONS FOR
- Space Optimization
- Corridor Breakaway, Compliant with NFPA 101 Section 7.2.1.4.3.
- Patient Privacy
- Frequent Breakaway for Patient Transports
APPLICATIONS
- ICU/CCUs
- Pressurized Isolation Rooms
- Smoke Rated Rooms
- Emergency Department Treatment Rooms
- Pre/Post Surgery Rooms
- Same Day Surgery Rooms
- Trauma Rooms
- Hospital Pharmacies
- Operating Rooms

MODELS
ProCare8300A: 2-panel automatic sliding door. Jamb mounted touch-less wave activation and overhead safety sensors. Newly designed to protect patients with safer transfers and promote healing by eliminating disruptions.
Dura-Care 7500A: 3-panel automatic sliding door. Jamb mounted touch-less wave activation and overhead safety sensors.
SOLUTIONS FOR
- Patient Privacy
- Frequent Breakaway for Patient Transports
- Infection Control
APPLICATIONS
- ICU/CCUs
- Pressurized Isolation Rooms
- Smoke Rated Rooms
- Emergency Department Treatment Rooms
- Pre/Post Surgery Rooms
- Same Day Surgery Rooms
- Trauma Rooms
- Hospital Pharmacies
- Operating Rooms

Surface applied manual door with single sliding panel and break out capabilities.
SOLUTIONS FOR
- Rough Opening Width Range: 35.3” x 106.3”
- Clear Door Opening Width Range: 35.3” - 91.5”
- Retrofit
APPLICATIONS
- Renovations
- Patient Bathrooms
- ICU/CCUs
- Pressurized Isolation Rooms
- Emergency Department Treatment Rooms
- Pre/Post Surgery Rooms
- Same Day Surgery Rooms
- Trauma Rooms