Welded panels and reinforcements keep the panels on track, reduce door damange and increase protection from flying debris and looting.
Add style and sophistication with 2" narrow stiles and special finishes (patterned wood laminate shown).
Welded panels and reinforcements keep the panels on track, reduce door damange and increase protection from flying debris and looting.
Add style and sophistication with 2" narrow stiles and special finishes (patterned wood laminate shown).
Compliant with Florida Building Code, Miami-Dade NOA Code, and ASTM E283. Tested to withstand winds up to 75psf and the impact of flyng debris.
Factory appllied environmentally-friendly 3M VHB eliminates time-consuming calking during install.
Compliant with Florida Building Code, Miami-Dade NOA Code, and ASTM E283. Tested to withstand winds up to 75psf and the impact of flyng debris.
Factory appllied environmentally-friendly 3M VHB eliminates time-consuming calking during install.
Designed to increase the structural resilience of essential facilities, the Dura-Storm Level E provides the utmost protection against windborne debris and hurricane force wind loads when evacuation is not an option.
Designed to increase the structural resilience of essential facilities, the Dura-Storm Level E provides the utmost protection against windborne debris and hurricane force wind loads when evacuation is not an option.

MODELS
Impact Rated Level E: Bi-Parting
-
Medium Stiles
-
Bi-part: 168” x 96”
-
Glass: 5/8”
Impact Rated: Bi-Parting and Single Slide
-
Narrow / Medium Stiles: +/- 75 PSF
-
Bi-part: 168” x 96”
-
Single Slide: 108” x 96”
-
Glass: 9/16”
Impact Rated: Bi-Parting Only
-
Medium Stiles - Steel Reinforced: +/- 55 PSF
-
Bi-part: 192” x 104” / 179.5” x 128”
-
Glass: 9/16
Non Impact Rated: Bi-Parting and Single Slide with Transom Option
-
Narrow / Medium Stiles: +/- 55 PSF
-
Bi-part: 168” x 96” (w/o transom) or 123.75” (w/ transom)
-
Single Slide with Optional Transom: 108” x 96” (w/o transom) or 123.75” (w/ transom)
-
Glass: ¼”, 1”
All door packages are custom manufactured to fit your job requirements up to ¼” increments. For sizes greater or smaller than typical, contact your authorized STANLEY Access Technologies Sales Representative.
Detailed Information
DESIGN | Single Slide or Bi-part |
---|---|
BREAKOUT | SX Panel on the 2000, SX and SO panels on the 3000 |
FINISH | Clear or Dark Bronze Anodized | OPTION: Special Finishes Available |
TYPICAL HEIGHT | 7’-8” (2.3m) |
CLEAR DOOR OPENING | Bipart 70.6” | Single Slide: 46.4” |
HEADER SIZE | 8” (203mm) High x 6” (152mm) Deep |
JAMB DIMENSION | 1 3/4” x 4 1/2” Option: 1 3/4” x 6” |
STILES | Narrow 2.0” or Medium 4.0" |
BOTTOM RAIL | 4" | OPTION: 6", 8", 10", 12" |
TYPICAL DOOR PANEL WEIGHT | Up to 220 Pounds Each (100kg) |
MAXIMUM PANEL WEIGHT | Up to 400lb (With Heavy Duty Option) |
DOOR PANEL MATERIAL | Aluminum |
POWER REQUIRED | 120 VAC, 50/60 HZ, 5 Amps Minimum | OPTION: Uninterrupted Power Supply |
DRIVE SYSTEM | 1/4 HP DC Motor, Gear Drive, Toothed belt | OPTION: Twin 1/4 HP DC Gear Driven Motors |
CONTROLS | Rocker Switch | OPTION: Rotary, Keyed Rotary Controls, Eco Pro |
CONTROLLER | High Resolution iQ Controller, Microprocessor Based, Safety Logic |
ACTIVATION/SAFETY SENSORS | 2 Combined Activation/Safety Sensors + Holding Doorway Holding Beams for added safety | OPTIONS: Mats, Wall Plates, Wireless Activation systems |
LOCKING | 5-point, Electric Solenoid Lock (Fail Safe/Fail Secure), Surface or Recessed Panic Hardware, Lock Guard, Armored Strike |
SECURITY OPTIONS | Alarm Contacts for remote monitoring of panel status, Security Strobes for theft deterrence |
CAMERA OPTIONS | Jamb Camera, Stan Camera |
TEMPERATURE RATING | -30F to 130F |
GLASS STOPS | 1/4", 1" | 9/16" Impact Glass |
MUNTINS | One 2" | OPTION: 4 1/4" |
THRESHOLD | Configurable Options |
TRANSOM | Optional on Non Impact package only |
CODES AND STANDARDS | ANSI A156.10, NFPA 101, UL, cUL, ICBO, BOCA, Florida Building Code, Miami-Dade County NOA Code Compliance, ASTM E283, Level E |
* All Specifications are subject to change. Please contact your local sales representative to ensure accuracy. |
NO | Illustration | Description | TYPE | Model | DWG | BIM/REVIT | |
---|---|---|---|---|---|---|---|
2.01 |
![]() |
Dura-Storm Impact | Bi-Part | 2000 | |||
2.02 |
![]() |
Dura-Storm Impact | Single Slide | 2000 | |||
2.03 |
![]() |
Dura-Storm Impact | Bi-Part | 3000 | |||
2.04 |
![]() |
Dura-Storm Impact | Single Slide | 3000 | |||
2.05 |
![]() |
Dura-Storm Non-Impact | Bi-Part | 2000 | |||
2.06 |
![]() |
Dura-Storm Non-Impact | Single Slide | 2000 | |||
2.07 |
![]() |
Dura-Storm Non-Impact | Bi-Part | 3000 | |||
2.08 |
![]() |
Dura-Storm Non-Impact | Single Slide | 3000 | |||
2.09 |
![]() |
Dura-Storm Impact Steel Reinforced | Bi-Part | 2000 | |||
2.10 |
![]() |
Dura-Storm Impact Steel Reinforced | Bi-Part | 3000 | |||
2.11 |
![]() |
Dura-Storm Impact Level E | 3000 | ||||
2.50 | Dura-Storm Threshold Options | 2000/3000 | |||||
2.60 | Dura-Storm Access Control Options | 2000/3000 | |||||
2.70 | Dura-Storm Transom Options | 2000/3000 |